Newco cb-2 参考指南

下载
页码 2
COMMERCIAL BARISTA DEC 2001 
= Power Save (Standby) - In this mode the tank temperature will be maintained at approximately 170 degrees when the set 
time has been reached.  Brew 1 light will flash about once every 10 seconds to indicate unit is in power save mode. 
= Power Down - In this mode the tank heater element will be disabled when the set time has been reached.  Brew 2 light 
will flash about once every 10 seconds to indicate unit is in power down mode. 
 
SEQUENCE OF PROGRAMMING STEPS FOR THE BARISTA CONTROLLER 
 
=
Depress and hold Cancel button until display lights up (Approx. 10 seconds). 
=
You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the following table. 
=
Use the Cancel button to cycle through the functions to find the one you wish to change. 
=
Use the BREW 1 button to lower the displayed value and the BREW 2 button to raise the value. Press Cancel to store the changed value and 
advance to next function. 
=
If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted below. 
 
CODE 
FUNCTION TO SET 
SET VALUES AVAILABLE 
LIGHTS ICON ADJACENT TO 
1A 
Brew 1 time  
OFF, 30 ounces – 255 ounces 
BREW 1 
1b 
Brew 2 time  
OFF, 30 ounces – 255 ounces 
BREW 2 
2a 
Dual volume- brew1 
Double dump feature 
ON or OFF 
Water filtering Brew 1 
2b 
Dual volume- brew2 
Double dump feature 
ON or OFF 
Water filtering Brew 2 
Visa-brew time     
OFF, 30  seconds – 2 ½ minutes 
BREW 1 and BREW 2 (both flashing) 
Water Temperature   1 
170 
°
F – 205 
°
F  
SERVICE 
Auto Arm 
ON or OFF 
HEATING, (flashing) 
6A 
Pre-infusion 1 mode 
ON or OFF 
BREW 1, (pulsing), COFFEE MONITOR 
6b 
Pre-infusion 2 mode 
ON or OFF 
BREW 2, (pulsing), COFFEE MONITOR 
Pulse brew mode 
ON or OFF 
BREW 1 and BREW 2 (pulsing) 
7A 
Pulse brew 1 time    2 
0 seconds – 60 seconds 
BREW 1 (pulsing) 
7b 
Pulse brew 2 time    3 
0 seconds – 60 seconds 
BREW 2 (pulsing) 
8A 
Audible alert mode 
ON or OFF 
None 
8b 
Audible alert no. of beeps 
OFF, 1 – 9 
None 
Coffee freshness monitor 
10 minutes – 2 hours 
COFFEE MONITOR 
10A 
Filtering flow rate 
OFF, 0.25 – 1.00 gal. / min 
WATER FILTERING 
10b 
Filter capacity     4 
OFF, 0.50 – 2.50 gal. X 100 
WATER FILTERING, (flashing) 
11 
Number of Brews 
Quantity, Clr 
BREW 1 and BREW 2 
13A Power 
mode 
Normal, Power Save, Power Down 
None (Displayed  P: n, P: s and P: d respectively) 
13b Power shutdown time    5 30 minutes – 4 hours None 
End 
None   6 
N/A None 
 
Brewer will remain in this sequence indefinitely until CANCEL button is pressed.  Heating icon will track heater operation. 
Hidden if pulse brew mode is OFF or brew 1 time is OFF. 
Hidden if pulse brew mode is OFF or brew 2 time is OFF. 
Hidden if filter flow rate is OFF. 
Hidden when power save mode is normal. 
Program mode will time out in 15 seconds at end of programming sequence.  
 
ERROR MESSAGES 
 
The following table explains the error messages which may be encountered on the brewer.  The error messages may be cleared 
by going into the program mode, using the brew buttons to display “Clr” and then pressing the cancel button. 
 
ERROR MESSAGE 
DESCRIPTION 
CAUSE 
Er1 
Fill run error 
The fill solenoid has either run for more than six minutes on the initial tank fill 
or 3 minutes in normal operation. 
Er2 
Heater run error 
The tank heater has run for more than 30 consecutive minutes. 
Er3 
Shorted probe 
Short in the thermistor circuit. 
Er4 
Open probe 
Break in the thermistor circuit. 
Ful 
Filter limit reached 
The selected filtering capacity of the filter has been reached