Newco ia ap 用户指南

下载
页码 6
OPERATION INSTRUCTIONS 
 
Coffee Preparation Procedures 
 
1) 
Place filter into brew basket. 
 
2) 
Put the proper amount of coffee into the filter. 
 
3) 
Slide the brew basket into holder. 
 
4) 
Place the appropriate empty decanter into position below the brew basket. For airpots first open lid and 
remove pump stem. For other dispensers remove the lid unless it is a brew through design. Turn power on by 
depressing the "On/Off switch located on the face plate to the left of the "Brew Start" switch. 
 
5) 
Press brew start switch. Note: a brew cycle may be initiated even if the heating light is on. 
 
6) 
If the autoarm feature is enabled the heating light will begin to flash indicating that the brewer is heating 
and will begin to brew immediately after the heating cycle is complete. Do not remove decanter. Brew cycle may 
be canceled by depressing the power switch. Light on power switch should go out and heating light should no 
longer be flashing. 
 
7) 
Hot water will be delivered through the sprayhead. This distributes the hot water evenly over the coffee 
bed within the brew basket. The coffee brew will drain from the brew basket into the decanter below. 
 
8) 
The Brewing light should continue to flash until all the liquid has finished flowing from the brew basket. Do 
not remove decanter until the brewing process has stopped and all liquid has stopped flowing from the 
brewbasket. 
 
9) 
The resultant coffee brew should be crystal clear and have the desired properties attainable through 
excellent extraction. 
 
10) 
To clean brew basket simply remove from brew rails and dump filter into waste basket. The brewing 
process, as described above, can now be started again. 
 
ACE INTELLI-BREW FEATURE DESCRIPTION 
 
Digital Brew Timing is accurate to within .1 seconds over the entire adjustment range of 30 to 240 seconds. Brew 
time adjustment knob may be turned down during the brew cycle until brewing stops. Can aid in setting the unit up. 
See Fig 1 on page 5 for setting information. 
 
Control Brew cycles the fill valve on and off during the brew cycle. This slows the entry of cold water into the tank 
and minimizes the mixing action caused by introducing a large volume of cold water into the tank at one time 
resulting in a 3-5 degree increase in brew temperature. 
 
Visa-Brew continues to flash the brewing light after the fill portion of the brew cycle has stopped alerting the user 
that the brewed hot coffee has not finished draining from the brew basket. this popular feature has been enhanced 
with an autocal feature. Simply turn the adjustment dial all the way up, start a normal brew cycle as described 
under the "OPERATION INSTRUCTIONS", and after the brewed coffee has quit dripping from the basket turn the 
dial down just until the light quits flashing. Visa Brew is now custom set for your machine, filters, and coffee. See 
Fig 1 on page 5 for setting information. 
 
Auto Power Save allows you to automatically save energy when the brewer is not in use for a specified length of 
time ranging from 30 to 240 minutes. By using the "Tank Heater Mode" switch located on the back of the brewer 
you may select one of the three operation modes. 
 
 
Mode I is the "Power Save" mode. In this mode the tank temperature will be maintained at approximately 
 
170 degrees when the "Run Time..." setting on the control board has been reached. Heating light will 
 
flash once every minute to indicate unit is in power save mode. 
 
Mode II is the "Normal" mode. In this mode the tank temperature will be maintained at the temperature 
 
set on the control board at all times.