BEFORE YOU  CALL
Visit our web site at
 www.frigidaire.com.
1-800-944-9044
 (United States)
1-800-668-4606 
(Canada)
PROBLEM CAUSE 
CORRECTION 
RUNNING OF REFRIGERATOR
 
Compressor does not run. 
• 
Refrigerator  control is set to 
OFF. 
• 
Refrigerator is in defrost cycle. 
 
 
• 
Plug at electrical outlet is 
disconnected. 
• 
House fuse blown or tripped 
circuit breaker. 
• 
Power outage. 
• 
Set refrigerator control. See Temperature Controls 
section. 
• 
This is normal for a fully automatic defrost refrigerator. 
The defrost cycle occurs periodically, lasting about 30 
minutes. 
• 
Ensure plug is tightly pushed into outlet. 
 
• 
Check/replace fuse with a 15 amp time-delay fuse.  
Reset circuit breaker. 
• 
Check house lights. Call local Electric Company. 
TEMPERATURES ARE TOO COLD
 
Freezer temperature too 
cold. Fresh Food 
temperature is satisfactory. 
• 
Freezer control is set too cold. 
• 
Set freezer control to a warmer setting. Allow 24 hours 
for temperature to stabilize. 
Fresh Food temperature 
too cold. Freezer 
temperature is satisfactory. 
• 
Fresh Food control is set too 
cold. 
• 
Set fresh food control to a warmer setting. Allow 24 
hours for temperature to stabilize. 
AUTOMATIC ICE MAKER
 
Ice maker is not making 
any ice. 
• 
Ice maker wire signal arm is in 
the “up” or OFF position.  
• 
Household water line valve is 
not open. 
• 
Freezer is not cold enough. 
 
• 
Saddle valve on cold water 
pipe is clogged or restricted by 
foreign material. 
• 
Move wire signal arm to the “down” or ON position. 
(side mounted) 
• 
Turn on household water line valve. 
 
• 
Set freeze control to a colder setting. Allow 24 hours 
for temperature to stabilize. 
• 
Turn off household water line valve. Remove valve. 
Ensure that valve is not a self-piercing saddle valve.       
Clean valve. Replace valve if necessary.  
Ice maker is not making 
enough ice. 
• 
Ice maker is producing less ice 
than you expect. 
• 
Freezer is not cold enough. 
 
• 
Household water line valve is 
not completely open. 
• 
Ice maker should produce 2 ½ to 3 pounds of ice 
every 24 hours. 
• 
Set freeze control to a colder setting. Allow 24 hours 
for temperature to stabilize. 
• 
Turn on household water line valve. 
Ice cubes are freezing 
together. 
• 
Ice cubes are not being used 
frequently enough. 
• 
Ice cubes are hollow (partially 
frozen cubes with water 
inside). 
• 
Remove ice container and discard ice from container. 
Ice maker will produce fresh supply. 
• 
The ice & water filter cartridge may be clogged. 
Replace filter cartridge. 
WATER DISPENSER
 
Dispenser will not 
dispense water. 
• 
Household water line valve is 
not open. 
• 
Freezer door is not closed. 
• 
Ice & water filter cartridge is 
clogged. 
• 
Open household water line valve. See PROBLEM 
section ICE MAKER IS NOT MAKING ANY ICE
• 
Ensure that freezer door is closed. 
• 
Replace filter cartridge. 
Water pressure is 
extremely low.
 
• 
Cut-off and cut-on pressures 
are too low (well systems 
only). 
• 
Reverse osmosis system is in 
regenerative phase. 
• 
Have someone turn up the cut-off and cut-on pressure 
on the water pump system (well systems only). 
 
• 
It is normal for a reverse osmosis system to be below 
20 psi during the regenerative phase.