Nortel 4134 安装指导

下载
页码 102
24
Nortel Secure Router 4134 hardware components fundamentals
You can also configure the 1- and 2-port T1/E1 Small Modules to operate
as Integrated Services Digital Network (ISDN) primary rate interface (PRI)
connections, providing 23 (T1) or 30 (E1) bearer channels (B-channel) for
data and 1 D-channel for signaling.
The 2-port T1/E1 Small Module provides either two T1 ports or two E1 ports.
Table 2
Cable and connectors
Port
Connector
Recommended
cable type
Minimum
cable length
Maximum
cable length
T1/E1
RJ-45
T1: Dual twisted
pair, 100 ohm,
CAT3 or better
E1: Dual
shielded twisted
pair, 120 ohms,
or dual 75 ohm
coax cables
None
T1: DSX1
(interior) from
0 to 655 ft.
DS1 (exterior)
from 0 to
approximately
15000 ft.
Table 3
Module LEDs
LED
Description
STAT
General module status:
Off: No power available to the module
Yellow: Out of service, or failed to initiate
Green: Power on and the module is operational.
LINK/STAT 1
Status of interface 1:
Off: Not connected or the interface is out of service.
Yellow: The interface is in a loopback mode or is running diagnostics
Green: The link or channel is active and receiving a valid signal
LINK/STAT 2
(applicable to
2-port module only)
Status of interface 2:
Off: Not connected or the interface is out of service.
Yellow: The interface is in a loopback mode or is running diagnostics
Green: The link or channel is active and receiving a valid signal
ISDN BRI S/T and ISDN BRI U Small Modules
You can use the ISDN BRI modules to provide backup network connectivity
if the primary interface fails. The Dial-on-Demand Routing (DDR) feature on
the ISDN BRI Small Modules enables you to configure the ISDN interface
as a backup interface.
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007
Copyright © 2007, Nortel Networks
.