Nortel 4134 安装指导

下载
页码 102
28
Nortel Secure Router 4134 hardware components fundamentals
You configure each serial port using the Command Line Interface (CLI). The
Secure Router 4134 detects any configuration mismatch with connected
cables and signals an error with a red LED.
Table 6
Cable and connectors
Port
Connector
Recommended
cable type
Minimum
cable length
Cable length
summary
Serial
Smart Serial
26-pin
V.35: Up to 11
twisted pairs
plus grounds to a
34-pin MRAC-34
connector
X.21: Up to 7
twisted pairs
plus ground to a
DB-15 connector
RS-232/V .28:
Up to 11 signals
plus ground to a
DB-25 connector
RS-449/V .11:
Up to 11 twisted
pairs plus ground
to a DB-37
connector
EIA-530/A: Up to
11 twisted pairs
plus ground to a
DB-25 connector
None
V.35, X.21,
RS-449/V.11,
EIA-530/A: Up to
1000 m (3280 ft)
at 100 Kbps, 100
m (328 ft) at 2
Mbps
RS-232/V.28:
Up to 100 m (328
ft) at 9600 bps,
10 m (33 ft) at
100 Kbps
Table 7
Maximum DTE cable lengths
DTE data rate
(kbps)
Maximum DTE cable lengths
RS-232C
V.35
RS449/422
RS530/422
56 or 64
10 ft (3.05 m)
4000 ft (1219.2
m)
4000 ft (1219.2
m)
4000 ft (1219.2
m)
224 or 256
N/A
3500 ft (1066.8
m)
1700 ft (518.16
m)
1700 ft (518.16
m)
896 or 1024
N/A
1700 ft (518.16
m)
350 ft (106.68 m)
350 ft (106.68 m)
N/A - not applicable (these rates cannot be used for RS-232C interface)
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007
Copyright © 2007, Nortel Networks
.