Interface modules for the Secure Router 4134
33
The following figure shows the 1-port DS3 Medium Module.
Figure 13
1-port DS3 Medium Module
Table 16
Cable and connectors
Port
Connector
Recommended
cable type
Minimum
cable length
Maximum
cable length
DS3
Two BNC
connectors —
one for transmit
and one for
receive
Two 75 ohm
unbalanced coax
cables (RG-179
typical)
None
450 ft (137.16 m)
Table 17
Module LEDs
LED
Description
LINK/STAT
Status of interface:
Off: Not connected or the interface is out of service.
Yellow: The interface is in a loopback mode or is running diagnostics
Green: The link or channel is active and receiving a valid signal
STAT
General module status:
Off: No power available to the module
Yellow: Out of service, or failed to initiate
Green: Power on and the module is operational.
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007