Connecting power cables
51
8
Ensure you are in configuration mode, then enter the following
command to set the replacement module to an active state:
chassis module <slot> no shutdown
9
To verify the module status, enter:
show chassis
—End—
If you encounter issues activating the replacement interface module, see
Nortel Secure Router 4134 — Troubleshooting (NN47263-700).
Connecting power cables
There are two types of power supply modules available for the Secure
Router 4134:
AC power supply module (standard or PoE) requiring an external AC
power source
DC power supply module requiring an external DC power source
Use the procedures in this section to connect AC and DC power cables to a
Secure Router 4134.
Connecting AC power cables
Average time to install one AC power cable: 1 minute.
CAUTION
ESD
Always wear an ESD-preventative wrist strap when connecting
cables or performing maintenance on a Secure Router 4134.
Ensure that the wrist strap makes contact with your skin.
Prerequisites
Ensure you have one or two appropriately rated AC power cords,
dependent on your configuration.
Ensure the power cord or cords are long enough that you can plug the
male end into a standard 110/220 V AC power outlet.
Procedure steps
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007
Copyright © 2007, Nortel Networks
.