Installing Secure Router 4134 hardware components
When the power supply is fully inserted, the front of the power supply
unit is flush with the rear panel of the router.
5
Secure the power supply in the chassis by tightening the two
retaining screws.
—End—
Procedure steps to replace a power supply unit
Step
Action
1
Use a Phillips screwdriver to loosen the two screws that secure the
power supply unit that you must replace.
2
Grasp the handle on the power supply unit.
3
Pull the power supply unit from the slot.
4
Place the power supply unit on antistatic material.
5
Insert the replacement power supply unit in the power supply slot.
6
Push the power supply unit gently, but firmly, to insert it fully into the
internal connection port.
When the power supply is fully inserted, the front of the power supply
unit is flush with the rear panel of the router.
7
Secure the power supply in the chassis by tightening the two
retaining screws.
—End—
Replacing a fan tray module
The Secure Router 4134 ships with the fan tray module installed. This
section contains instructions for replacing a fan tray module.
Average time to install or replace a fan tray module: 1 minute.
CAUTION
Risk of equipment damage
The fan is essential for maintaining optimal system operating
temperature. If you plan to replace the fan tray module while the
system power is on, ensure you have another fan tray module
ready to insert immediately. Watch the fan status LED for alerts.
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007
Copyright © 2007, Nortel Networks
.