Nortel 5399 安装指南

下载
页码 132
4-9
Chapter 4    Troubleshooting Procedures
Model 5399 Remote Access Concentrator Module Hardware Installation Guide
Table 4-3. Errors from Last ERPC Layer Invocation
Table 4-4. Errors from Last Read Request
Error
Description
H/W errors
The Remote Access Concentrator sensed a hardware error
during message transmission or reception. This error
indicates a fault with the Remote Access Concentrator LAN
interface. Use the net command to isolate the problem (see
net on page 3-19).
Msgs from
wrong host
The Remote Access Concentrator received a message from
an incorrect host. This indicates that the Remote Access
Concentrator received, and ignored, an unsolicited packet.
Rsp T/O’s
The Remote Access Concentrator never received a
correctly formatted response from the correct host, or any
response from any load server hosts.
Msgs of
wrong type
The correct host sent a message to the Remote Access
Concentrator, but the message was not a correctly
formatted response to the transmitted request.
Error
Description
Msgs with wrong
size
The correct host responded to the Read Request, but
the data size is incorrect.
ERPC layer errors
See
.
Aborts rx’d
The host’s BFS transmitted an abort in response to
the Remote Access Concentrator’s Read Request.
Run erpcd –D on the host to obtain more
information.