Voice Gateway 4000 Hardware Manual
2-2
303145-A Rev. 00
Rack Mounting
Install the rack mount by bolting it into the 19-inch equipment rack using the four 
front panel mounting holes. The mounting holes on the front panel are set on 
RTMA standard spacing and fit into any standard equipment rack with 7 inches of 
available vertical space.
Equipment slide rails are recommended for installation and provide easier access 
to the unit for maintenance and troubleshooting. If you use slide rails, secure the 
unit into position by installing four retaining screws in the four holes of the front 
panel. 
Caution: 
The front panel may not support the weight of a fully loaded system.
Warning: 
Failure to install the four retaining screws can cause the chassis to 
slide forward if the cabinet is tilted or vibrated resulting in possible 
mechanical or electrical damage to the unit or injury to operating personnel.
Danger: 
Electrical power must be connected with a certified power cord for 
the country where the equipment is used.