Nortel 450-24t 用户指南

下载
页码 400
Using the Console Interface
309978-D Rev 01
3-81
Proxy
Allows the switch to consolidate IGMP Host Membership Reports received on its 
downstream ports and to generate a consolidated proxy report for forwarding to its 
upstream neighbor.
This field affects all VLANs (for example, if you disable Proxy for the VLAN specified 
in the screen’s VLAN field, Proxy is disabled for ALL VLANs). You cannot set the 
Proxy field value to Disabled unless the Snooping field value is Enabled.
Default
Enabled
Range
Enabled, Disabled
Robust Value
Allows you to set the switch to offset expected packet loss on a subnet. If packet 
losses on a subnet are unacceptably high, the Robust Value field can be increased 
to a higher value.
This field affects only the VLAN specified in the screen’s VLAN field (for example, if 
you change the robust value on the VLAN specified in the screen’s VLAN field, other 
VLANs are not affected).
Default
2
Range
1 to 64
Query Time
Allows you to control the number of IGMP messages allowed on the subnet by 
varying the Query Interval (the Query Interval is the interval between general 
queries sent by the IP multicast router).
This field affects only the VLAN specified in the screen’s VLAN field (for example, if 
you change the Query Time value field on the VLAN specified in the screen’s VLAN 
field, other VLANs are not affected).
Default
125 seconds
Range
1 to 512 seconds
Set Router Ports
Selects the IGMP version according to the IGMPv1 (Version 1) or IGMPv2 
 
(Version 2) standard (see RFC 2236).
Use this field in conjunction with the Static Router Ports field (see next field 
description) to select the IGMP version to set. You can also use this field to view 
which Static Router Ports are set to Version 1 or to Version 2. Use the spacebar to 
toggle between the two versions and view the Static Router Ports settings. This field 
affects all VLANs (for example, if you change the value of the Set Router Ports field 
on the VLAN specified in the screen’s VLAN field, all VLANs are affected).
Default
Version 1
Range
Version 1, Version 2
(continued)
Table 3-29.
IGMP Configuration Screen Fields
 (continued)
Field
Description