Nortel 450-24t 用户指南

下载
页码 400
Using the BayStack 450 10/100/1000 Series Switch
D-14
309978-D Rev 01
LECs and VLAN Membership
The following configuration rules apply:
You cannot assign a LEC as a tagged VLAN member.
The PVID value for a LEC is read-only and must always equal its VLAN ID.
LEC VLAN members do not support priority.
A LEC can only be a member of one VLAN.
A VLAN can only have one LEC member. 
LECs can be configured as members of port-based VLANs only; LECs cannot 
be configured as members of protocol-based VLANs.
Console Differences
Many of the features that are available to your BayStack 450 switch 
Ethernet-based ports cannot be supported by ATM. In those cases the VPorts that 
represent the ATM LECs will either be hidden or displayed as read-only fields.
The following BayStack 450 switch features are not supported by the BayStack 
450-2M3/2S3 MDA:
MultiLink Trunking
Port Mirroring
Filtering of untagged/tagged frames
VLAN Traffic Class Priority
Change of PVID
Protocol-based VLANs
VLAN tagging
Rate Limiting