Nortel 15000 安装指导

下载
页码 34
308687-B Rev 00
1-1
 
Chapter 1
About the AC Power Unit
The Versalar routers can operate with AC or DC source power. AC power is 
provided by a separate, optional AC power unit mounted in the rack beneath the 
router. 
The Versalar 25000 ships with two AC power supplies as shown in Figure 1-1, 
while the Versalar 15000 ships with one. For redundancy and high-availability 
operation, the Versalar 15000 can have an additional power supply installed (for a 
total of two), while the Versalar 25000 can have an additional external AC power 
rack mounted (for a total of four power supplies). 
Note: 
Each AC power supply needs to be mapped to a corresponding DC 
power supply. If you have a separate AC power unit (with its two AC power 
supplies), you must ensure that there are two corresponding DC power 
supplies in the Versalar router. Similarly, if you have two separate AC power 
units for redundancy and high-availability operation, as in the Versalar 25000, 
you should ensure that the four AC power supplies map to four DC power 
supplies in the chassis.