show t3 ds3 summary
308689-B Rev 00
179
 
MTU
Displays largest frame size that can be received by the 
MCT3 channel. Anything larger than the MTU will be 
discarded.
Setup Alarm Threshold
Minimum amount of time required before entering (or 
exiting) an alarm state due to changes on the DS3.
Clear Alarm Threshold
Code Sent
Displays type of code last sent across the MCT3 circuit 
by the device. Possible values are: sendnocode (sending 
looped or normal data), sendlinecode (sending a request 
for a line loopback), sendpayloadcode (sending a 
request for a payload loopback), and sendds1loopcode 
(sending a request for a DS1 loopback). 
Cable Length
Parameter set according to cable length. Possible values 
are short (less than 225 feet), or long (greater than 225 
feet).
Payload Type
Type of payload to be sent through the DS3 connector. 
Possible values are: not yet configured (selected) (1), 
channelized DS1 (2), fractional DS3 (3) and clear channel 
DS3 (4). 
T3 over Mcoc3 Ds3 summary
Slot/Conn/Channel
Identifier for the slot, OC3 connector, T3 channel.
Administrative State
Displays administrative state.
Operational State
Displays operational state. 
Alarms
Displays alarm state.
Linecoding
Displays the variety of zero code suppression used on the 
link, which in turn affects a number of its characteristics. 
The only value allowed here is B3ZS. 
Framing
Framing mode. Possible values here are autodetect, 
C-bit, or M23.
Actual Framing
Actual framing currently used on the line. Possible values 
are C-bit, or M23. Note that this can be different than the 
configured line type when the autodetect value is used.
Pri/Sec Clock
Displays configured primary/secondary source of the Tx 
clock for the MCT3 channel interface. 
Actual Clock
Displays clock source currently in use by the MCT3 