Nortel 15000 发行公告

下载
页码 18
Known Anomalies for the Versalar Switch Router 15000
10
302773-E Rev 00
Access Lines
Title:
E1 SONET Statistics Fail to Stabilize Following Failover to Slot 5 [New]
Number:
125728-1
Description:
When an E1 processor card (capE1) is removed from a slot and the ARM card in slot 
5 takes over, bit interleaved parity (BIP) errors and far end block errors (FEBE) are 
excessive and continue to increment indefinitely.
Title:
Cannot Police Values Higher Than T1 Rates
Number:
122595-2
Description:
The QoS values for the CIR and Burst rates do not support levels greater than 
1.54 Mb/s.
Title:
Channelized Access Processor Failover Not Maintained During System Reboot
Number:
120681-1 and 122383-1
Description:
If a channelized access processor fails over to a redundancy module in slot 5, the 
system does not repeat the failover if it reboots.
Workaround:
To prevent the loss of access services, replace the failed access processor.
Title:
Fractional Loop for T3 and T1 Lines Functions Incorrectly with No Protocol 
Configured [New]
Number:
117638-3
Description:
The fractional loopback command for T3 and T1 lines does not work when no 
protocol is configured.
Workaround:
Add a layer 2 protocol, such as PPP or Frame Relay, to the interface.
Title:
show t1 qos summary
 Command Displays Excessive Queues as “up”
Number:
114230-1
Description:
If you assign more than 256 queues to access channels on the upper or lower group of 
three MCT3 ports, and enter the 
show t1 qos summary
 command, the BCC 
erroneously displays the queues exceeding the 256 limitation as “up” (operational).
Workaround:
Do not exceed the maximum number of transmit queues (256) on either the upper or 
lower group of three MCT3 ports on a slot. (For more information about queue 
allocation, see Configuring Physical and Data Link Services for the Versalar Switch 
Router 15000
.)
Use the
 
show t1 summary
 command to identify any queues that exceed the 256 
limitation as “queMisCfg” (that is, queue misconfigured).