Nortel 1110 用户指南

下载
页码 560
276
Nortel IP Phone 1110
Ensure the host Call Server is equipped with a Signaling Server that
runs the Line TPS application.
If an AC power adapter is required, ensure the approved Nortel AC
adapter (model number N0089601) is used. See
First-time installation
You must first install an IP telephony node with the Communication Server.
For information about installing an IP telephony node, see Signaling Server
Installation and Commissioning (NN43001-312) 
or IP Line Fundamentals
(NN43100-500)
.
CAUTION
Do not plug your IP Phone 1110 into an ISDN connection. Severe
damage can result.
Configuring the IP Phone 1110
You must configure the IP Phone 1110 before you can use it. Use Procedure
58 to configure the IP Phone 1110 for the first time.
Procedure 57
Configuring the IP Phone 1110
Step
Action
1
Configure a virtual loop on the Call Server using LD 97.
For more information about configuring a virtual loop, see IP
Line Fundamentals (NN43100-500) 
and Software Input Output
Administration (NN43001-611)
.
2
Configure the IP Phone 1110 on the Call Server using LD 11. At
the prompt, enter the following
REQ:chg
TYPE: 1110
For more information about configuring the IP Phone 1110 using LD
11, see Software Input Output Administration (NN43001-611).
Nortel Communication Server 1000
IP Phones Fundamentals
NN43001-368
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003–2007, Nortel Networks
.