Installation and configuration
395
— Getting Started Card
Ensure 1 Software License exists for each IP Phone 1150E being
installed.
Ensure the host Call Server is equipped with a voice Gateway Media
Card and a Signaling Server with the Line TPS application.
If an AC power adapter is required, ensure the approved Nortel global
power supply (model number N0089601) is used. See
First-time installation
You must first install an IP telephony node with the Communication Server.
For information about installing an IP telephony node, see Signaling Server
Installation and Commissioning (NN43001-312) 
or IP Line Fundamentals
(NN43100-500)
.
CAUTION
Damage to Equipment
Do not plug your IP Phone 1150E into an ISDN connection.
Severe damage can result.
Configuring the IP Phone 1150E
You must configure the IP Phone 1150E before you can use it. Use
to configure the
IP Phone 1150E for the first time.
Procedure 80
Configuring an IP Phone 1150E
Step
Action
1
Configure a virtual loop on the Call Server using LD 97.
For more information about configuring a virtual loop, see IP
Line Fundamentals (NN43100-500) 
and Software Input Output
Administration (NN43001-611)
.
2
Configure the IP Phone 1150E on the Call Server using LD 11. At
the prompt, enter the following:
REQ: chg
TYPE: 1150
For more information about configuring the IP Phone 1150E using
LD 11, see Software Input Output Administration (NN43001-611).