The display power cable has three wires, white, red and black. Red is the 
positive (+) lead, black is negative (–) or ground. The white wire is un-
used by your unit and should be capped. Make sure to attach the in-line 
fuse holder to the red lead as close to the power source as possible. 
For example, if you have to extend the power cable to the power bus or 
battery, attach one end of the fuse holder directly to the power bus or 
battery. This will protect both the unit and the power cable in the event 
of a short. 
This unit has reverse polarity protection. No damage will occur if the 
power wires are reversed. However, the unit will not work until the 
wires are attached correctly. 
Power Diagram A 
 
Use this method if you are powering the display unit and a GPS mod-
ule or the display unit and a NMEA 2000 network. (Fuses may be dif-
ferent from those shown.). 
The network and any NMEA 2000 devices, including the GPS 
module,  
will not operate unless the NMEA 2000 Power Cable is 
connected to power. The NMEA 2000 power cable must be connected 
to power even if your only NMEA 2000 device is the GPS module and it 
is connected to the display unit's Network socket. (However,  never 
connect multiple power sources to a NMEA 2000 network.
 If you 
have a network that is already powered, see diagram B on page 33.)
 
Shield
Mandatory 
network 
power-off 
switch 
Black 
Black
Red 
Recommended 
display unit 
power-off switch
To unit 
12 volt DC 
power source 
Data Cable 
NMEA 2000 
Power Cable 
3-amp fuse 
3-amp fuse 
Display Unit 
Power Cable 
 
 
     
   
White 
(unused)