Technical Specifications
 
Summit Family Switches Hardware Installation Guide
190
Input current 
1.45 A @ 115 V
 (low-line)
0.65 A @ 230 V
 (high-line)
Line frequency range 
47 to 63 Hz
Inrush current
30 A @ 115 V, 60 A @ 230 V
Power supply cord type 
AC
Power supply input socket 
IEC 320 C14
Power cord input plug 
IEC 320 C13
Power cord wall plug 
Refer to 
.
Power supply cord gauge
18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Efficiency
81%
Heat dissipation (BTU)
392.4
Heat dissipation (Watts)
115
Power consumption (BTU)
170.6
Power consumption (Watts)
392.4
Safety Standards
North American Safety of ITE
UL 60950-1:2003 1st Ed., Listed Device (US)
CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE
EN 60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE
CB Report & Certificate per IEC 60950-1:2001 Country Deviations 
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE 
FCC CFR 47 part 15 Class A (USA) 
ICES-003 Class A (Canada) 
European EMC standards 
EN 55022:1998 Class A 
EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 
EN 61000-3-2,3 (Harmonics & Flicker) 
ETSI EN 300 386:2001 (EMC Telecommunications)
89/336/EEC EMC Directive
International EMC certifications
CISPR 22:1997 Class A (International Emissions)
CISPR 24:1997 Class A (International Immunity)
IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, 
Criteria A
IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A 
IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A 
IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A 
IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. 
RMS, Criteria A
IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, 
Criteria C
Country-specific
VCCI Class A (Japan Emissions) 
AS/NZS 3548 ACA (Australia Emissions) 
CNS 13438:1997 Class A (BSMI-Taiwan) 
MIC Mark, EMC Approval (Korea) 
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications) 
ETSI EN 300 019 (Environmental for Telecommunications) 
Table 28: Summit X350 Series Switch Technical Specifications (Continued)