34
Extreme Networks Consolidated Hardware Guide
Summary of Common Switch Features
Identifying ZX GBIC Rev 03 Modules
To identify the type of ZX GBIC module you have, look at the label on the top of the ZX GBIC module. 
If you see one of the following on the label, you have a ZX GBIC Rev 03 module:
DVA-1203 sticker near the top of the label that covers the Extreme Networks logo
ZX GBIC (1203) text near the top of the label
ZX GBIC Rev 03 text near the center of the label
Requirements for the LX100 GBIC
This section describes the requirements for the LX100 GBIC. Read the information in this section before 
you install an LX100 GBIC. 
The Summit24e2 switch does not support the LX100 GBIC. Do not install an LX100 GBIC into the 
Summit24e2 switch.
If you have an Alpine 3800 series switch populated with a GM-4Xi module, do one of the following:
Install a maximum of three LX100 GBICs per GM-4Xi module; the fourth GBIC slot must remain 
empty
Install two or less LX100 GBICs per GM-4Xi module and leave the remaining GBIC slots empty
Install two or less LX100 GBICs per GM-4Xi module and install any combination of the following 
GBICs into the empty slots:
1000BASE-SX
Table 11: LX70 GBIC specifications
Parameter
Minimum
Typical
Maximum
Transceiver
Optical output power
0 dBm
3 dBm
5.2 dBm
Center wavelength
1540 nm
1550 nm
1570 nm
Receiver
Optical input power sensitivity
-22 dBm
Optical input power maximum
-3 dBm
Operating wavelength
1270 nm
1570 nm
Table 12: LX100 GBIC specifications
Parameter
Minimum
Typical
Maximum
Transceiver
Optical output power
1 dBm
3 dBm
5 dBm
Center wavelength
1546 nm
1551 nm
1557 nm
Receiver
Optical input power sensitivity
-29 dBm
Optical input power maximum
-7 dBm
Operating wavelength
1546 nm
1551 nm