Extreme 3802 安装指南

下载
页码 390
 
BlackDiamond Power Supplies
Extreme Networks Consolidated "i" and "e" Series Hardware Installation Guide
229
The BlackDiamond 6800 series switch generates SNMP traps for the following events:
AC power source fails
Power supply fails
Power supply is removed
For more information about planning your site and power requirements, see “Meeting Power 
Requirements” in Cha
pter 2. For more information about the specifications of the BlackDiamond 6800 
series switch power supplies, see Table 85 on page 334.
220 VAC Power Supplies
If you install a 220 VAC power supply in the BlackDiamond 6800 series chassis, 220 Volts of power is 
required for full operation. If 110VAC power is supplied, some BlackDiamond I/O modules might not 
power up.
The MSM performs power calculations and powers up the maximum number of I/O modules from left 
(slot 1) to right (slot 8) in the BlackDiamond 6808, or top (slot 1) to bottom (slot 4 in the BlackDiamond 
6804 and slot 16 in the BlackDiamond 6816). A module is skipped if that module is not within the 
power budget. Using 110 VAC, only eight modules in the BlackDiamond 6816, four modules in the 
BlackDiamond 6808, and two modules in the BlackDiamond 6804 are powered on.
The BlackDiamond switch does not support installing a combination of the old 220 VAC PSUs (part 
number 50012) with the new iPower 220 VAC PSUs (part number 50021) in the same chassis.
The 220 VAC power supply ships with one L6-20P (locking) power cable.
220 VAC power supplies slide in from the front of the chassis, as illustrated in Figure 127.
Figure 127: 220 VAC power supplies in a BlackDiamond 6808 or a BlackDiamond 6804
Table 46 describes the LED activity on the 220 VAC power supply
AC IN
BD_028
DC OUT
50021
POWER
DC OUT
AC IN
50021
POWER