Extreme 10808 安装指南

下载
页码 180
I/O Modules
 
BlackDiamond 8800 Series Switches Hardware Installation Guide
29
CAUTION
BlackDiamond a-series modules require specific minimum versions of ExtremeXOS software to be recognized by the 
MSM (see 
). Software builds earlier than the listed versions do not support the specified I/O modules. 
If you attempt to install one of these I/O modules before upgrading the software on your MSM, the module will not 
be recognized by the software and it will not power up. The following error messages are similar to the messages 
that may be displayed on the console or in the log. (Samples represent an unrecognized module in slot 2.)
On the console: ERROR: 
Unknown cardtype in slot 2 - please program the eeprom
In the log: 
<Error: HAL.Card.Error> MSM-A: Unable to read cardtype for slot 2
 
G48Ta I/O Module
The G48Ta I/O module (
) has 48 autosensing 10/100/1000BASE-T ports that use standard 
RJ-45 connectors. 
Figure 12: G48Ta I/O Module
The default configuration of the G48Ta I/O module is as follows. All ports:
Are added to the default VLAN as untagged
Inherit the properties of the default VLAN (for example, protocol type and VLANid)
Operate in autonegotiation mode
The G48Ta I/O module has the following LEDs:
Module status
Module diagnostics
Port status
For information about the LEDs and their activity on the G48Ta I/O module, see 
Table 4: Minimum Software Versions for BlackDiamond 8800 a-Series Modules
Module
Required ExtremeXOS version
G48Ta
ExtremeXOS 11.5.0 or later
G48Xa
ExtremeXOS 11.5.0 or later
10G4Xa
ExtremeXOS 11.6.0 or later
10G4Ca
ExtremeXOS 12.0.1 or later
Module status LEDs
ASP048
10/100/1000BASE-T
ports