Intermec 2460 补充手册

下载
页码 24
Trakker Antares 246X Stationary Terminal User’s Manual Addendum
14
Interleaved 2 of 5 Enhancements
Description:
Interleaved 2 of 5 (I 2 of 5) is a high-density, self-checking, continuous numeric
symbology. With firmware version 6.15 and later, you can now set two additional
parameters.
Syntax:
CAdata
Additional values for data are:
95
Case code (6 or 14) with check digit verified but discarded
96
Variable length with check digit verified but discarded
Existing values for data are 0, 2-32, 97, 98, and 99. Only the new values for data are
described in this section. For more information about the existing values, see
“Interleaved 2 of 5” in Chapter 8, “Configuration Command Reference,” in your user’s
manual.
Default:
Disabled
Scan:
One of these bar codes:
Enable Case Code With Check Digit 
Enable Variable Length With Check Digit
Verified But Discarded
Verified But Discarded
*$+CA95*
*$+CA96*
*$+CA95*
*$+CA96*
Keypad Control
Description:
Enables or disables the keypad. When you disable the keypad, you cannot use the
keypad to enter information into the terminal.
Syntax:
KEdata
Acceptable values for data are:
0
Disable keypad
1
Enable keypad
Default:
Enabled
Scan:
One of these bar codes:
Disable Keypad
Enable Keypad
*$+KE0*
*$+KE1*
*$+KE0*
*$+KE1*