Lexicon MC-12 用户指南

下载
页码 106
Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
 
7.3.2.2 MC-12 Response 
The MC-12 will reset, clear any saved system and effect parameters in Nonvolatile RAM, and restore the 
factory default system and effect parameters.  After reset the MC-12 will go through a soft power-up 
initialization.  This includes transmitting the “Wakeup Notification Packet”. 
7.3.3  MC-1 Send IR Command (MC-12, MC-1) 
Transmits MC-1 IR command key codes to the MC-12.  
 
This command has been maintained for backward compatibility to the MC-1.  The MC-1 IR code 
functionality has been mapped to the MC-12 IR code functionality as per the MC-1 to MC-12 IR code 
table. MC-12 users should use the command described in 
7.3.3.1  Command Packet Description 
 
Application Header: 
  
Command DC_CMD_IR 0x14 
Data Count 
0x01 
Application Data: 
  
Data[0] KeyCode nn 
 
7.3.3.2 Data Description 
 KeyCode: 
 
 
Data Type: 
Unsigned 8 bit integer 
  Valid 
Values: 
7.3.3.3 MC-12 Response 
The KeyCode is processed as a valid IR code.  No acknowledgment will be sent from MC-12. 
7.3.3.4 Data Validation 
The KeyCode data will be verified as a legal IR code.  If the Code is not valid the MC-12 will not respond. 
7.3.4  Get Unit Configuration (MC-12, MC-1) 
Request to MC-12 for its current unit configuration. 
 
This command is supported for backward compatibility.  MC-12 users should use the command described 
in 
. MC-12 will respond with “Unit Configuration Packet”.  The 
HOST should use this information to determine if any information saved by the HOST is current. 
7.3.4.1  Command Packet Description 
Application Header: 
  
Command DC_CMD_GET_CONFIG 
0x15 
Data Count 
0x00 
Application Data: 
  
  
N/A 
  
 
© 2005 Harman Specialty Group All rights reserved. 
 