MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
7.3.19.1  Command Packet Description 
 
Application Header: 
  
Command DC_CMD_SET_SYS_BALANCE  0x22 
Data Count  1 
0x01 
Application Data: 
  
Data[0] Value 
nn 
 
7.3.19.2 Data Description 
Value: 
Data Type: 
 
Unsigned 8 bit integer. 
Maximum Value: 32 
Conversion: 
 
0 =  Left 
16 = Center 
32 = Right 
7.3.19.3 MC-12 Response 
The MC-12 will assign the value from the packet to the system balance.  
7.3.19.4 Data Validation 
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command 
and transmit a DC_NAK command with an error code DC_INVALID_DATA. 
7.3.20  Set Front/Back Balance (MC-12, MC-1) 
Commands MC-12 to set the front/back balance to the value in this packet. 
 
This command has been maintained for backward compatibility with MC-1.  In order to maintain backward 
compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data 
Description.  MC-12 users should be using the command described in 
 
7.3.20.1 Packet Description 
Application Header: 
  
Command DC_CMD_SET_FRONT_BACK_BALANCE 
0x23 
Data Count  1 
0x01 
Application Data: 
  
Data[0] Value 
nn 
 
7.3.20.2 Data Description 
Value: 
Data Type: 
 
Unsigned 8 bit integer. 
Max: 
  32 
Conversion: 
 
0 =  Front 
16 = Center 
32 = Back 
7.3.20.3 MC-12 Response 