Lexicon MC-12 用户指南

下载
页码 106
Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
a NAK packet with a DC_INVALID_INPUT error code. The MC-12 will transmit a NAK packet with a  
DC_ERR_READ_ONLY error code  for read only parameters. 
 
7.3.38  MC-12 Set Parameter Value by Id, No Run (MC-12) 
MC-12 Set Parameter by Id command sets the parameter value equal to the value sent in the command 
packet and does not run the appropriate functional changes associated with changing the given parameter. 
7.3.38.1  Command Packet Description 
Application Header: 
  
Command MC_CMD_SET_SYS_PARAM_VALUE_BY_ID_NO_RUN 0x37 
Data Count  24 
0x18 
Application Data: 
  
Data[0] ParamId(LSB) 
nn 
Data[1] ParamId(MSB) 
nn 
Data[2] ParamType 
nn 
Data[3-23] Value[0 
-20] 
nn nn 
nn… 
7.3.38.2 Data Description 
Same as 
 
7.3.39  MC-12 Get Unit Configuration (MC-12) 
Request to MC-12 for its current unit configuration.  MC-12 will respond with “Unit Configuration 
Packet”.  The HOST should use this information to determine if any information saved by the HOST is 
current. 
7.3.39.1  Command Packet Description 
Application Header: 
  
Command MC_CMD_GET_CONFIG 
0x38 
Data Count 
0x00 
Application Data: 
  
  
N/A 
  
 
© 2005 Harman Specialty Group All rights reserved. 
 
40 of 106