Lexicon MC-12 用户指南

下载
页码 106
Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
7.3.52  MC-12 Set Zone2 Volume (MC-12) 
Commands MC-12 to set the Zone 2 volume with the value in this packet. 
 
7.3.52.1  Command Packet Description 
  
Application Header: 
Command MC_CMD_SET_ZONE2_VOLUME  0x45 
Data Count  1 
0x01 
Application Data: 
  
Data[0] Value 
nn 
 
7.3.52.2 Data Description 
Value: 
Data Type: 
 
Signed 8 bit integer (2’s compliment) 
Max: 
  +12 
(0x0C) 
(12dB) 
Min: 
 
 
-80 (0xB0) (-80 dB) 
 
7.3.52.3 MC-12 Response 
The MC-12 will assign the value from the packet to the Zone 2 volume.  
7.3.52.4 Data Validation 
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command 
and transmit a NAK command with an error code DC_INVALID_DATA. 
 
 
7.3.53  MC-12 Set Zone2 Left/Right Balance (MC-12) 
Commands MC-12 to set the Zone 2 balance to the value in this packet. 
 
7.3.53.1 Packet Description 
  
Application Header: 
Command MC_CMD_SET_ZONE2_BALANCE  0x46 
Data Count  1 
0x01 
Application Data: 
  
Data[0] Value 
nn 
 
7.3.53.2 Data Description 
Value: 
Data Type: 
 
Signed 8 bit integer (2’s compliment) 
Max: 
 
 
+16 (0x10) (Full Right) 
Min: 
  -16 
(0xF0) 
(Full 
Left) 
   
7.3.53.3 MC-12 Response 
The MC-12 will assign the value from the packet to the Zone 2 balance. 
7.3.53.4 Data Validation 
© 2005 Harman Specialty Group All rights reserved. 
 
52 of 106