Fedders air bear right angle 用户指南

下载
页码 4
Dimensions
Capacity in CFM
600
800
1000
1200
1400
1600
1800
2000
Pressure Drop
Inches W.G.
.03
.05
.07
.10
.14
.18
.22
.27
Specifications
Application
The air cleaner is is to be installed  in a forced air
heating, cooling, and ventilating system. It should be
installed in the system such that all the system air is
circulated through the air cleaner. The air cleaner will
only remove the airborne contaminants delivered to it;
therefore maximum performance is obtained when the
system blower is set for continuous operation.
Installation Requirements
Locate the air cleaner in the return air duct next to the
blower compartment. In this location, the blower
motor and cooling coils will be kept clean. 
Air Conditioning
The air cleaner should be installed upstream of the
cooling coil to keep the coil clean and reduce air
conditioning coil maintenance. Improved cooling
efficiency is the result of clean coils which directly
affects energy costs. Failure to replace filter cartridge
can cause damage to cooling system and increase
utility bills.
Sheet Metal Installation
This right angle media air cleaner is adaptable to all
new or existing residential forced air furnace and
cooling systems with Highboy Space Saver or offset
installation.
Air Cleaner Installation and Maintenance
This right angle media air cleaner has been designed
specifically for highboy furnaces and direct installation
to your heating and cooling system return air duct. 
The duct opening of your air cleaner is supplied with
an adjustable inlet flange.
The unit is shipped with the flange set at 24” x 8”. If
the incoming duct is 24” x 8”, attach the duct directly
to the flange and secure with sheet metal screws
through the pre-drilled holes.
If flange requires adjustment to 24” x 10”, remove the
five #6 sheet metal screws securing the flange to the
cabinet. Adjust flange to 24” x 10” and secure with
screws. Proceed with installation.
Traditional Installation 
of air cleaner
Installation of Right Angle
Media Air Cleaner
Installation
2