Fedders mister 50 用户指南

下载
页码 16
6
16.  Install the saddle valve (from parts bag) per
instructions printed on valve packaging.
17.  Place the compression nut on one end of the
water tubing, with the threads facing toward
the tubing end.
18.  Slide the Delrin sleeve (from parts bag) over
the tubing with the short beveled end toward
the nut. Leave 5/32” of tubing protruding
beyond the end of the delrin sleeve.
19.  Press the insert (from parts bag) into the water
tubing. If the tubing is too small to allow the
insert to enter, place the end of the tubing in
hot water to soften the plastic. Place the insert
against a flat surface and press the tubing
onto the insert.
20.  Fasten tubing assembly securely to the saddle
valve, but do not connect to humidifier.
21.  With the end of the tubing in a bucket or pan,
turn on the saddle valve to void the tubing
assemblly of any debris.
22.  Cut off any excess length of water tubing and
connect it to the humidifier using the
compression nut, sleeve and insert as defined
in steps 17, 18, and 19 above.
23.  Turn the saddle valve on and check the tubing
and humidifier for leaks.
Installation
Humidifier
Delrin Sleeve
Saddle Valve
Water Line
Compression Nut
Insert
Insert
Water  connection