INSTALLATION
• Make sure that your oven has not suffered any damage during transport (defor-
med door or door seal, etc.). If you see any signs of damage, contact your dea-
ler before use.
• Check the power voltage. If there is a PERMANENT undervoltage (200-210 volts),
consult your electrical installer.
Location
• The appliance should be installed at a distance of 85 cm above the floor.
• Place the oven on a flat and horizontal surface, away from any source of heat or steam.
•  Make sure that nothing obstructs the ventilation louvers at the back of the
appliance.
• Make sure the electrical plug will be accessible after installation.
• Do not use your appliance immediately (wait approx. 1-2 hours) after transfer from a
cold place to a warm place as condensation may cause a malfunction.
• Your installation must be protected by a 10 Amp thermal fuse.
• It is mandatory to use a power point with a ground terminal, connected in accordan-
ce with current safety regulations.
• In your electrical installation, provide a device that is accessible to the installer, capable
of separating the appliance from the mains power and whose contact opening is at
least 3 mm at all of the poles.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
Electrical connection
Before connection