Electrical Connection
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord. 
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
 
1. Disconnect Power.
2. Remove hold-down screw and terminal block cover.
A. Terminal block cover 
B. Hold-down screw
C. External ground conductor 
screw
D. Center, silver-colored terminal 
block screw
E. Neutral ground wire
F. Hole below terminal block 
opening
A B
C
D
E
F
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove screws from a 3/4" (19 mm) UL listed strain relief 
(UL marking on strain relief). Put tabs of the two clamp 
sections into hole below terminal block opening so that 
 
one tab is pointing up and the other is pointing down, and 
hold in place. Tighten strain relief screws enough to hold two 
clamp sections together. 
A. Strain relief tab pointing up
B. Hole below terminal block 
opening
C. Clamp section
D. Strain relief tab pointing down
A
B
C
D
Put power supply cord through strain relief. Be sure that wire 
insulation on power supply cord is inside strain relief. Strain 
relief should have a tight fit with the dryer cabinet and be in 
 
a horizontal position. Do not further tighten strain relief 
screws at this point. 
Style 2: Direct wire strain relief
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
Unscrew removable conduit connector and any screws from 
a 3/4" (19 mm) UL listed strain relief (UL marking on strain 
relief). Put threaded section of strain relief through hole 
below terminal block opening. Reaching inside terminal