3com S7906E 安装指导

下载
页码 2621
 
1-7 
 
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured 
in this section take effect on all Ethernet ports automatically.  
 
Configuring Errored Frame Event Detection 
An errored frame event occurs when the number of detected error frames over a specific interval 
exceeds the predefined threshold.  
Follow these steps to configure errored frame event detection: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure the errored frame 
event detection interval 
oam errored-frame period 
period-value 
Optional 
1 second by default 
Configure the errored frame 
event triggering threshold 
oam errored-frame threshold 
threshold-value 
Optional 
1 by default 
 
Configuring Errored Frame Period Event Detection 
An errored frame period event occurs if the number of frame errors in specific number of received 
frames exceeds the predefined threshold.  
Follow these steps to configure errored frame period event detection: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure the errored frame 
period event detection period 
oam errored-frame-period 
period 
period-value 
Optional 
1000 milliseconds by default 
Configure the errored frame 
period event triggering 
threshold 
oam errored-frame-period 
threshold 
threshold-value 
Optional 
1 by default 
 
Configuring Errored Frame Seconds Event Detection 
An errored frame seconds event occurs when the number of error frame seconds detected on a port 
over a detection interval exceeds the error threshold. 
Follow these steps to configure errored frame seconds event detection: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure the errored frame 
seconds event detection 
interval 
oam errored-frame-seconds 
period 
period-value 
Optional 
60 second by default