3com S7906E 参考指南

下载
页码 2327
 
1-8 
Related commands: rmon prialarm
Examples 
# Display the configuration of all private alarm entries. 
<Sysname> display rmon prialarm 
PrialarmEntry 1 owned by user1 is VALID. 
  Samples type          : absolute 
  Variable formula      : (.1.3.6.1.2.1.16.1.1.1.6.1*100/.1.3.6.1.2.1.16.1.1.1.5.1) 
  Description           : ifUtilization.GigabitEthernet2/0/1 
  Sampling interval     : 10(sec) 
  Rising threshold      : 80(linked with event 1) 
  Falling threshold     : 5(linked with event 2) 
  When startup enables  : risingOrFallingAlarm 
  This entry will exist : forever 
  Latest value          : 85 
Table 1-5 display rmon prialarm command output description 
Field 
Description 
PrialarmEntry 
The entry of the private alarm table 
owned by 
Owner of the entry, user1 in this example 
VALID 
Status of the entry identified by the index (VALID means the 
entry is valid, and UNDERCREATION means invalid. You can 
use the display rmon command to view the invalid entry; while 
with the display current-configuration and display this 
commands you cannot view the corresponding rmon 
commands.) 
Samples type 
Sampling type, whose value can be absolute or delta. 
Variable formula 
Variable formula 
Sampling interval 
Sampling interval, in seconds. The system performs absolute 
sample or delta sample to sampling variables according to the 
sampling interval. 
Rising threshold 
Alarm rising threshold. An event is triggered when the sampled 
value is greater than or equal to this threshold. 
Falling threshold 
Alarm falling threshold. An event is triggered when the sampled 
value is less than or equal to this threshold. 
linked with event 
Event index associated with the prialarm 
When startup enables 
How can an alarm be triggered 
This entry will exist 
The lifetime of the entry, which can be forever or span the 
specified period 
Latest value 
The count result of the last sample 
 
display rmon statistics 
Syntax 
display rmon statistics [ interface-type interface-number