Xerox 8830 folder 服务手册

下载
页码 51
September 2001
88XX Series Folder Operator Manual   19
Cross Programs Submenu
Use this submenu to select the cross folding options.
1.  Go to the “Cross Programs” submenu
in the Numeric Control Panel
in the Alphanumeric Control Panel
u
OPERATOR
U2
CROSS PROGRAMS
2.  The default option is shown :
in the Numeric Control Panel
in the Alphanumeric Control Panel
u202
STANDARD
Lower right dot
flashing
3.  Use the scroll key to select the desired option and press “Enter to
select it.
With selecting “STANDARD” [ u2.01 ], for example,
an E size print (36”x48”) with a program 8.5”x11” will
be folded with an output dimension 8.5”x11”. The length
of each panel (b) is not equal.
The same print could be folded with the same fan
program with the option “EQUAL” [ u2.02 ] because
the folder automatically divides the width of the print to
obtain equal panels.
The purpose of the “EQUAL” option is to obtain a folded print
more flat and folded with one less cross fold. That is why it does not
work with all sizes and styles. Only when a few millimeters of the
cross folding depth is modified, is it possible to obtain a folded print
without prefolds. The “EQUAL” option does not produce results
with Ericsson, Afnor, French and Wallets program (some of these
styles already have an output equal). Besides, it is possible to fold
equal panels only with some kind of paper rolls.
ROLL
UNI/DIN fold depth
ANSI/ARCH fold depth
914 (36”)
305
305
900
300
300
864
297
288
610
305
305
Selecting “CROSS OFF” [ u2.03 ] will
bypass the Cross Folder. The print will be fan
folded only and stacked in the Rear Print
Tray.
To activate the cross folder after a “Cross
Off” selection, select one of the two options:
“Standard” or “Equal”.
4.  Select EXIT [ u2.00 ] to rise one level.
Cross
programs
u 2
Exit
u 2.00
Equal
u 2.01
Standard
u 2.02
Cross
off
u 2.03
11,3” - 12”
11”
6-7”