Xerox 2045 补充手册
C
ALIBRATION
45
Restoring default calibration measurements
Use the following procedure to return to factory default calibration measurements.
T
O
RESTORE
DEFAULT
CALIBRATION
MEASUREMENTS
1 In the Calibrator dialog box, click Restore Device.
2 Click OK to restore the preset default calibration set.
N
OTE
:
Restore Device applies only to the currently selected calibration set.
Calibrating with the DTP32
Using the DTP32 densitometer, you can measure color patches generated by the digital press
and automatically download the measurements to the Fiery EXP6000/EXP5000.
and automatically download the measurements to the Fiery EXP6000/EXP5000.
N
OTE
:
Before you use ColorWise Pro Tools and the DTP32 to calibrate the Fiery EXP6000/
EXP5000, follow the instructions on
T
O
CALIBRATE
THE
F
IERY
EXP6000/EXP5000
USING
THE
DTP32
1 Start Calibrator.
For instructions, see
.
2 In the Select Measurement Method pane, choose X-Rite DTP32.
3 In the Check Print Settings pane, choose a calibration set.
If more than one option appears, choose the appropriate calibration set for the type of screen
and media you use most often.
and media you use most often.
N
OTE
:
For this calibration to take effect, the calibration set must be associated with one or
more output profiles. The default calibration set is already associated with the default output
profile. You do not need to make any new associations.
profile. You do not need to make any new associations.
4 Click Print in the Generate Measurement Page pane.
The Print Options dialog box appears.