Xerox 8400B 用户指南

下载
页码 129
 
 
PrinterMap User Guide 
74 
 
• 
Status (severity of the alarm condition) 
• 
Date and Time the alarm is detected 
• 
Printer Name 
• 
Alarm description 
• 
Comment (used for acknowledgment) 
 
The comment field remains blank until the alarm is acknowledged. The Alarm Log 
displays a color coded status box for each alarm condition. The table below shows 
severity and resulting status color for each alarm condition detected by 
PrinterMap. 
Table 10 Alarm Condition to Status Color Mapping 
Alarm Condition
 
Severity
 
Status Color 
Low Paper
 
Warning 
 
Yellow
 
Low Toner
 
Warning
 
Yellow
 
Service Requested
 
Warning
 
Yellow
 
No Paper
 
Critical
 
Red
 
No Toner
 
Critical
 
Red
 
Door Open
 
Critical
 
Red
 
Jammed
 
Critical
 
Red
 
Offline
 
Critical
 
Red
 
Unknown
 
Critical
 
Red 
 
If PrinterMap is unable to determine the cause of an alarm condition, “Invalid 
Alarm Type” is displayed. 
NOTE:   A printer’s status on the topology and related alarms in the log file may 
not show the same severity color indicator (critical/red vs. 
warning/yellow). The values  that determine overall status indications 
and specific alarm indications are provided to PrinterMap by each 
printer from two different notifications. PrinterMap is dependent on the 
printer notification implementation for severity indicators accuracy. For 
example, this occurs on the Xerox 4517 printer, where  “No Paper” in 
the envelope feeder results in status indication of warning/yellow 
displayed on the topology map. The logged alarms are critical/red due to 
an open door. This is the alarm that an empty envelope feeder creates on 
the Xerox 4517.