Xerox 750P 用户指南

下载
页码 118
Advanced Features and Troubleshooting Manual
97
Regulatory Information for Phaser 750 Printers
Declaration of conformity
for 220-230 VAC equipment
Tektronix, Inc.
Color Printing and Imaging Division
P.O. Box 1000
Wilsonville, Oregon 97070-1000 U.S.A.
declares, under our sole responsibility, that the products
Phaser 750 printer (Z750) 
to which this declaration relates, is in conformity with the following standard(s) or other 
normative document(s): 
Following the provisions of the Low Voltage Directive 73/23/EEC
EN 60950:1992
(IEC 950)
Safety of Information Technology Equipment including Electrical Business 
Equipment
Following the provisions of the Electromagnetic Compatibility Directive 89/336/EEC,
EN55022:1992
(CISPR 22)
Limits and methods of measurement of radio interference characteristics of 
Information technology equipment. Class B.
EN61000-3-2:1995
(IEC61000-3-2)
Part 3: Limits - Section 2: Limits for harmonic current emissions (equipment 
input current £ 16A per phase).
EN61000-3-3:1994
(IEC61000-3-3)
Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in 
low-voltage supply systems for equipment with rated current £ 16A.
EN55024:1997
Information technology equipment – Immunity characteristics
 – Limits and methods of measurement.
Immunity 
Phenomena
Basic Standard
Test Specification
Performance Level
Criteria
Electrostatic 
Discharge
EC61000-4-2:1995
10 discharges minimum 
each polarity per test 
point
6kV Contact
12kV Air
A
A
Radiated Rf 
field, AM
IEC61000-4-3:1995
80-100 MHz
3V/m,
80 percent
AM @1kHz
A
Fast Burst 
Transients
IEC61000-4-4:1995
5/50 Tr/Th ns
5kHz repetition 
frequency
0.5kV Signal Lines 
1kV AC Mains
A
A
Line Surge on 
AC mains
EC61000-4-5;1995
combination wave; 
Tr=1.2uS, Th=50uS
 2.0kV Com. mode
 2.0kV Diff. mode
A
A
Conducted RF, 
AM
EC61000-4-6;1996
0.15 to 80 MHz
3V, 80 percent 
AM@1kHz
A