ICOM IC-7000 说明手册

下载
页码 166
70
5
FUNCTIONS FOR RECEIVE
5
D
Fix mode
Displays signals within the specified frequency range.
The selected band conditions can be observed at a
glance when using this mode.
q Set a mode and frequency.
w Select G
G--1
1 (Scope).
e Push 
[F-3
F
FI
IX
X
]
momentarily to select the fix
mode.
• “O” and readout frequency indicator appear when the
fix mode is selected.
r Push 
[F-4
S
SP
PD
D
]
momentarily to select the sweep
speed.
• “≈” or “≈≈” appears when Slow speed or Fast speed is
selected, respectively.
t Push 
[F-1
S
SP
PN
N
]
one or more times to select the
desired steps.
• ±10, 25, 50, 100 and 250 kHz are available.
• Push and hold 
[F-1
S
SP
PN
N
]
for 1 sec. to select the ±10
kHz step.
• “<
<” or “>
>” indicates when the displayed frequency is out
of range. The scope center position can be set to the
displayed frequency by pushing and holding 
[F-3
F
FI
IX
X
]
for 1 sec.
• The simple band scope operates in the peak level hold
mode. Peak levels are displayed in the background of
the current spectrum in a different color until the receive
frequency changes. This can be cleared by pushing
and holding 
[F-2
H
HL
LD
D
]
for 1 sec., or deactivated in the
scope set mode. (p. 72)
y Push 
[F-2
H
HL
LD
D
]
to freeze the current spectrum dis-
play.
• “H” appears while the function is in use.
NOTE: 
If there is a lot of signal noise, turn the pre-
amp OFF and the attenuator ON (p. 72) to reduce
the input level and improve the readability of the
scope.
[MENU/GRP]
[F-1]
[F-2] [F-3] [F-4]
• Push and hold 
[MENU/GRP]
for 1 sec. once or twice
to select the menu group G
G (Graphic).
• Push 
[MENU/GRP]
momentarily one or more times to
select the menu G
G--1
1 (Scope).