Location:
The Membrane Switch is located on the front face 
plate.
Test Procedures:
 
There are two methods for testing the membrane 
switch. The easiest method is to use the built in test 
mode. Refer to the Programing Section for Service 
Tools/Test Switches. If for some reason you can't get 
into the program modes, or brewer won't power up, 
FIG. 14-1  MEMBRANE SWITCH
you can test it with an ohmmeter or continuity tester. 
Refer to the schematic to trace the appropriate pins.
NOTE: Pin 1 is the static shield & will not provide a 
reading to the other pins. There are two commons 
in this circuit, pins 9 & 10.
Disconnect brewer from power source before discon-
necting ribbon cable from control board.
Removal and Replacement:
1.    Disconnect the ribbon cable from 10-pin connector 
on the control board.
2.  Gently peel the membrane switch from the front 
face plate assembly.
4  Remove any adhesive that remains on the front 
face plate.
5.  Remove the adhesive backing from the new mem-
brane switch. Insert the ribbon cable through the slot 
in the front face plate and apply the membrane switch 
to the front face plate.
6.  Connect the ribbon cable to the 10-pin connector on 
the control board making sure every pin on the control 
board is inserted into the ribbon cable connector.
Helpful
Hint
FIG. 14-2  MEMBRANE SWITCH CONTINUITY
MEMBRANE SWITCH
39132 100609
Wrap a thin paper clip around each meter lead 
and extend past the tip by ¼" - ½". You may 
need to sand off the clear coating on some clips!