Location:
 
The  contactor  is  located  on  the  component 
bracket inside the lower rear panel.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the black wire from the contactor coil 
to  the  limit  thermostat  and  black  wire  from  the 
red wire on the main harness on two wire 240V 
models.
3.  Check the voltage across the red wire and black 
wire with a voltmeter. The indication must be:
 
a.) 240 volts ac for 240 volt models,
 
b.) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described refer to the Wiring 
Diagrams and check the wiring harness.
5.  Check  for  continuity  between  the    left  and  right 
terminals on the contactor coil.
If  continuity  is  present  as  described,  reconnect  the 
wires and proceed to #6
If continuity is not present as described, replace the 
contactor.
6.  Check the voltage across the upper left terminal 
and the upper right terminal on the contactor with 
a voltmeter. Connect the dispenser to the power 
source. The indication must be:
 
a.) 240 volts ac for 240 volt models,
 
b.) 230 volts ac for 230 volt models.
7.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #8.
If voltage is not present as described, refer to the wiring 
diagrams and check the wiring harness.
8.  Check for continuity across the terminals on the 
left side of the contactor by manually closing the 
contacts.  Continuity  must  not  present  when  the 
contact is released.
9.  Check for continuity across the terminals on the 
right side of the contactor by manually closing the 
contacts. Continuity must not be present when the 
contact is released.
If continuity is present as described, the contactor is 
operating properly.
If continuity is not present as described, replace the 
contactor.
SERVICE (cont.)
Contactor
FIG. 13 CONTACTOR
P1785