Bunn U3 服务手册

下载
页码 41
Page 15
J2
SET
     L
OC
K
LO
CK
SE
T
TL
1
TL
2
TL
3
TL
4
TL
5
J1
P09.60
FIG. 4 CONTACTOR
CONTACTOR
Location:
 
The contactor is located on the left front of the 
component bracket
Test Procedures:
1.  Disconnect the brewer from the power source.
A. 10/08V, 10/40V, 380V THREE WIRE MODELS, 
380V and 440V FOUR WIRE MODELS 
 
Disconnect the black wire from the contactor coil 
to the limit thermostat and black wire from the 
white wire on the main harness. 
B. 08V  or  40V  TWO  WIRE  MODELS  (Prior  to 
#  U300004095),  08V  and  40V  THREE  WIRE 
MODELS
 
Disconnect the black wire from the contactor coil 
to the limit thermostat and black wire from the red 
wire on the main harness. 
C. 30V MODELS (S/N U300004095 - UP)
 
Disconnect the red wire from contactor coil to the 
limit thermostat and the black wire from the main 
harness.
3.  Connect the brewer to the power source. 
4.  Check the voltage across the coil wire and the wire 
from the the main harness.The indication must 
be:
SERVICE (cont.)
 
a) 10 volts ac for three wire 10/08, 10/40 
volt and 380 volt models.
 
b) 30 volts ac for two wire 30 volt models.
 
c) 08 or 40 volts ac for two wire 08 or 40 volt 
models.
 
d) 0 or 54 volts ac for four wire 80 or 440 
volt models.
5.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described refer to the Wiring 
Diagrams and check the brewer wiring harness.
6.  Check for continuity between the black leads on 
the contactor coil or the left and right terminals 
on the contactor coil on 30V models.
If continuity is present as described, reconnect the 
wires and proceed to #7.
If continuity is not present as described, replace the 
contactor.
7.  On all brewers, with a voltmeter, check the voltage 
across the upper left terminal and the upper right 
terminal on the contactor. Connect the brewer to 
the power source. The indication must be:
 
a) 10 volts ac for three wire 10/08, 10/40 
volt and 380 volt models.
 
b) 30 volts ac for two wire 30 volt models.
 
c) 08 or 40 volts ac for two wire 08 or 40 volt 
models.
 
d) 0 or 54 volts ac for four wire 80 or 440 
volt models.
8.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #9.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
10060  080900