Fishfinder Alarms Setup
.
Note: If a fishfinder is not detected, the alarm setup windows are
greyed out.
Offtrack Alarm
Switches the off-track alarm on or off
Switches the off-track alarm on or off
OFF
ON
ON
Offtrack Alarm XTE
If the Offtrack Alarm is set to ON, an alarm is triggered
when the XTE for any current navigation, exceeds the
value that you have specified.
If the Offtrack Alarm is set to ON, an alarm is triggered
when the XTE for any current navigation, exceeds the
value that you have specified.
0.3nm
0.01 - 9.99nm
(or equivalent in the
selected Distance
Unit)
0.01 - 9.99nm
(or equivalent in the
selected Distance
Unit)
MENU ITEM
OPTION
Fish Alarm
Switches the fish alarm on or off.
Switches the fish alarm on or off.
OFF
ON
ON
Fish Alarm Sensitivity
If the Fish Alarm is set to ON, an alarm is triggered
when the fish return strength reaches the sensitivity that
you specify.
If the Fish Alarm is set to ON, an alarm is triggered
when the fish return strength reaches the sensitivity that
you specify.
5%
10% - 100%
10% - 100%
Fish Alarm Depth Limits
If the Fish Alarm and this alarm is set to ON, an alarm is
triggered (2 beeps) if any target meets the sensitivity
level and is within the Shallow Fish Limit and Deep Fish
Limit that you specify.
If the Fish Alarm and this alarm is set to ON, an alarm is
triggered (2 beeps) if any target meets the sensitivity
level and is within the Shallow Fish Limit and Deep Fish
Limit that you specify.
OFF
ON
ON
Shallow Fish Limit
Specifies the lower value for the Fish Alarm Depth LImit.
Specifies the lower value for the Fish Alarm Depth LImit.
2ft
(0002ft - 1000ft)
(0002ft - 1000ft)
Deep Fish Limit
Specifies the upper value for the Fish Alarm Depth LImit
Specifies the upper value for the Fish Alarm Depth LImit
1000ft
(0002ft - 5000ft)
(0002ft - 5000ft)
MENU ITEM
OPTIONS
Shallow Depth Alarm
Switches the shallow depth alarm on or off.
If a DSM is not connected, this cannot be set.
Switches the shallow depth alarm on or off.
If a DSM is not connected, this cannot be set.
OFF
ON
ON
Shallow Depth Alarm Value
If the Shallow Depth Alarm is set to ON, an alarm is trig-
gered if the depth drops below the value you specify.
If the Shallow Depth Alarm is set to ON, an alarm is trig-
gered if the depth drops below the value you specify.
5ft
(0002ft - maximum
range of transducer)
(0002ft - maximum
range of transducer)
Deep Depth Alarm
Switches the deep depth alarm on or off.
If a DSM is not connected, this cannot be set.
Switches the deep depth alarm on or off.
If a DSM is not connected, this cannot be set.
OFF
ON
ON
Deep Depth Alarm Value
If the Deep Depth Alarm is set to ON, an alarm is trig-
gered if the depth exceeds the value that you specify.
If the Deep Depth Alarm is set to ON, an alarm is trig-
gered if the depth exceeds the value that you specify.
MENU ITEM
OPTION