D-Link DAS-4192DC 用户手册
154
Alarm Definition
AMS LCT
Software Operation Guide
NE Model
Module Name
Alarm Name
Default Severity
Alarm Description
DISABLED
Information
The port is disabled
GE Port
MISSING
Major
GE Port is off-line
GE Port
NOT_OPERABLE
Major
GE Port is not operable
STP_LEARN
Information
GE port is transited to STP-learnning state
STP_BLOCK
Information
GE port is transited to STP-blocking state
DISABLED
Information
GE port is disabled
Alarm Relay Module
MISSING
Major
Alarm relay module is off-line
MISSING
Major
Alarm relay port is off-line
RELAY_ABNORMAL
Major
The alarm relay port is under abnormal
status
status
Alarm Relay Port
DISABLED
Information
The port is disabled
MISSING
Major
SHDSL module is off-line
TEMP
Major
Temperature is over the threshold
VOL
Major
Voltage is below the threshold
MISMATCH
Major
Planned type and online type are
mismatched
mismatched
SHDSL Module
NOT_OPERABLE
Major
Line card is not operable
ES_NE_15_MIN
Minor
15-min near end ES is over the threshold
SES_NE_15_MIN
Minor
15-min near end SES is over the threshold
UAS_NE_15_MIN
Minor
15-min near end UAS is over the threshold
TCA_CRC_NE_15MIN
Minor
15-min near end CRC is over the threshold
TCA_LOSW_NE_15MIN
Minor
15-min near end LOSW is over the
threshold
threshold
TCA_SNR_NE
Minor
Near end SNR margin is over the threshold
TCA_ATTN_NE
Minor
Near end loop attenuation is over the
threshold
threshold
OPI
Minor
Operation state change indication
LOS
Minor
Loss of signal (FOH lost bit)
SEGA
Minor
Segment anomaly - CRC anomaly (FOH
sega bit)
sega bit)
LPR
Minor
Loss of power - power status (FOH ps bit)
SEGD
Minor
Segment defect - LOSW defect (FOH segd
bit)
bit)
PBO_NE
Minor
Near end enhanced power back off
DEVFAULT_NE
Minor
Near end device fault - Diagnostic or
self-test fault
self-test fault
DCCONT_NE
Minor
Near end DC continuity fault - interfere
with span powering
with span powering
LOSW_NE
Minor
Near end LOSW failure
INI_CFG_NE
Minor
Near end indicates Far end not able to
support requested configuration
support requested configuration
INI_PROTOCOL_NE
Minor
Near end indicates incompatible protocol
used by Far end
used by Far end
NOPEER
Minor
No peer detected
PBO_FE
Minor
Far end enhanced power back off
DEVFAULT_FE
Minor
Far end device fault - Diagnostic or
self-test fault
self-test fault
DCCONT_FE
Minor
Far end DC continuity fault - interfere with
span powering
span powering
LOSW_FE
Minor
Far end LOSW failure
INI_CFG_FE
Minor
Far end indicates Near end not able to
support requested configuration
support requested configuration
INI_PROTOCOL_FE
Minor
Far end indicates incompatible protocol
used by Near end
used by Near end
SHDSL Port
DISABLED
Information
The port is disabled
PWR1_FAIL
Warning Power1
failed
PWR2_FAIL
Warning Power2
failed
PWR1_NOT_OPERABLE
Major
Power1 is not operable
DAS4672
Chassis
PWR2_NOT_OPERABLE
Major
Power2 is not operable