Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
equivalent feet (meters) for each vent piece used in the system.
Example vent system
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
back pressure and air turbulence that greatly reduce
performance.
Determine Range Blower Setting
This cooktop is equipped with a dual range blower. It is shipped
from the factory in the low range for most installations. If the
equivalent duct length exceeds 30 ft (9.1 m), it must be converted
to high range. Do not convert the blower to high range for shorter
lengths; this will cause excessive noise and conditioned air loss.
Convert blower before installing into countertop if necessary.
from the factory in the low range for most installations. If the
equivalent duct length exceeds 30 ft (9.1 m), it must be converted
to high range. Do not convert the blower to high range for shorter
lengths; this will cause excessive noise and conditioned air loss.
Convert blower before installing into countertop if necessary.
To Convert to High Range:
1. Place cooktop on floor with front edge and plenum down.
2. Remove the four #10 - 32 locknuts (A) that attach the blower
motor assembly to the blower exhaust scroll.
3. Remove the blower motor assembly (B) from the blower
exhaust scroll (E).
4. Slowly reach into the blower exhaust scroll opening and
remove the retainer (C).
5. Gently remove the restrictor ring (D).
6. Place the motor assembly back on the studs of the blower
exhaust scroll.
7. Reattach the four #10-32 locknuts to secure the blower motor
assembly back to the blower exhaust scroll.
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m)
(0.8 m)
90° elbow
5.0 ft
(1.5 m)
(1.5 m)
6" (15.2 cm)
wall cap
wall cap
0.0 ft
(0.0 m)
(0.0 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) transition
4.5 ft
(1.4 m)
(1.4 m)
6" (15.2 cm) to 3
¹⁄₄" x 10"
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
(0.3 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
transition
transition
9.0 ft
(2.7 m)
(2.7 m)
6" (15.2 cm) to 3
¹⁄₄" x 10"
(8.3 cm x 25.4 cm) 90° elbow
transition
transition
5.0 ft
(1.5 m)
(1.5 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm)
90° elbow
5.0 ft
(1.5 m)
(1.5 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm)
flat elbow
12.0 ft
(3.7 m)
(3.7 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm)
wall cap
0.0 ft
(0.0 m)
(0.0 m)
5" to 6" (12.7 cm to 15.2 cm)
transition
transition
1 ft
(0.3 m)
(0.3 m)
1- 90° elbow
= 5 ft (1.5 m)
8 ft (2.4 m) straight
= 8 ft (2.4 m)
1 - wall cap
= 0 ft (0 m)
System length
= 13 ft (3.9 m)
A. #10 - 32 locknut
B. Blower motor and wheel assembly
B. Blower motor and wheel assembly
C. Retainer
D. Restrictor ring
D. Restrictor ring
E. Exhaust scroll
F. Blower wheel guard
90˚ elbow
2 ft
(0.6 m)
6 ft (1.8 m)
wall cap
A B
C
D
E
F