Canon vb-s31D 手册

下载
页码 185
40
Administrator Password
(1) [Password] 
Set the administrator password. Up to eight (single-
byte) ASCII characters (space or printable 
characters) can be used. The factory default setting is 
“camera”. If the Admin Viewer, Admin Tools, etc., are 
connected, terminate the connection before changing 
the password. 
(2) [Confirm Password] 
Enter the same password as above for confirmation. 
LAN
(1) [LAN Interface] 
Select [Auto], [Full Duplex] or [Half Duplex]. Normally 
[Auto] is used. 
(2) [Maximum Packet Size] 
Enter the maximum transmission unit. Normally there 
is no need to change the default setting of 1500. 
Note
When using ADSL, setting the maximum packet size to a slightly 
lower value may increase sending efficiency. 
IPv4
(1) [IPv4 Address Setting Method] 
Select [Manual] or [Auto (DHCP)] in the address 
setting method. If [Manual] is selected, directly enter 
the values according to the environment in which the 
camera is used. If [Auto (DHCP)] is selected, the value 
automatically acquired from the DHCP server will be 
entered in [IPv4 Address], [Subnet Mask] and [IPv4 
Default Gateway Address].
(2) [IPv4 Address] 
If [Manual] is specified in (1), enter a fixed IP address. 
(3) [Subnet Mask] 
If [Manual] is specified in (1), enter the designated 
subnet mask values for each network. 
[Network] 
Setting Administrator Password, LAN, IP Address, DNS, etc
The following can be set here. 
• Administrator Password
Set the administrator password. 
• LAN
Set the IP address and other items needed to 
establish a LAN connection. 
• IPv4
Set IPv4 address. 
• IPv6
Set IPv6 address. 
• DNS
Set the name server address, host name and 
DDNS registration. 
• mDNS
This will configure settings for using multicast 
DNS.
• SNMP
Configure the necessary settings to use SNMP. 
Important
• To ensure system security, be sure to change the 
administrator password. If it is not changed, a message 
prompting change of the password will appear continuously 
in the upper portion of the Setting Menu. The message will 
not disappear until the password is changed. Do not forget 
the new password. 
• Press the reset switch to restore factory default settings if you 
have forgotten the administrator password (p. 167). Note, 
however, that this will reset all camera settings to factory 
default settings except for date and time. 
• [Administrator Password] and [Access Control] > 
[Administrator Password] (p. 64) are the same. If you set one 
[Administrator Password], the setting will be reflected in the 
other [Administrator Password].
Important
• The camera may become inaccessible from the active web 
browser if [LAN Interface] or [Maximum Packet Size] settings 
are changed. Check beforehand the precautions in 
• Set [Maximum Packet Size] to 1280 or greater if using IPv6.