Using the OSD Menu
Calibration without a PC (
When "User 1-7" under "Picture Mode" is selected, you can perform calibration using an external sensor, without using
the computer.
The supported external sensors are Konika Minolta Display Color Analyzers CA-310 and CA-210. Be sure to also read
the instruction manual of the CA-310 and CA-210.
1.  Connect the display color analyzer to the USB port of the main unit.
2.  Open the OSD menu and select "Adjustment"→"Detail Settings"→"Calibration".
Set each target value.
3.  Select "Start" with the SET button.
Please follow the information indicated on the screen.
4.  Initialize the sensor.
Set the mode dial of the Universal Measuring Probe to "0-CAL".
Select "OK" with the SET button on the and perform initialization.
5.  Place the sensor facing the center of the main unit.
Set the mode dial of the Universal Measuring Probe to "MEAS" and place the probe as shown below according to
the displayed content. Select "OK" with the SET button on the display controller and perform calibration.
Konica Minolta Universal Measuring Probe
CA-310 support: CA-PU32, CA-PU35
CA-210 support: CA-PU12, CA-PU15
Konica Minolta
Display Color Analyzer CA-310, CA-
210
Main Unit
6.  Finish calibration.
When the message "Calibration is completed." appears, select "OK" with the SET button.
•  If the message "Calibration error." is displayed.
Calibration has been terminated due to an error. The main unit returns to the state before calibration (
•  To cancel calibration
Select "Cancel" with the SET button during calibration. The main unit returns to the state before calibration.