ASUS ASMB8-iKVM 用户指南

下载
页码 106
ASUS ASMB8-iKVM
4-17
4.4.9 PEF
Platform Event Filtering (PEF)
 provides a mechanism for configuring the BMC to take 
selected actions on event messages that it receives or has internally generated. These 
actions include operations such as system power-off, system reset, as well as triggering the 
generation of an alert. A PEF implementation is recommended to provide at least 16 entries 
in the event filter table. A subset of these entries should be pre-configured for common 
system failure events, such as over-temperature, power system failure, fan failure events, etc.
To open PEF Management Settings page, click Configurations > PEF from the main menu. 
A sample screenshot of PEF Management Settings Page is shown in the screen shot below.
1. 
PEF ID:
 This field displays the ID for the newly configured PEF entry (read-only).
2. 
Filter configuration:
 Check box to enable the PEF settings.
3. 
Event Filter Action:
 Check box to enable PEF Alert action. This is a mandatory field.
4. 
Event Severity: 
To choose any one of the Event severity from the list.
5. 
Sensor Name:
 To choose the particular sensor from the sensor list.
6. 
Add:
 To add the new event filter entry and return to Event filter list.
7. 
Modify:
 To modify the existing entries.
8. 
Cancel:
 To cancel the modification and return to Event filter list.