Synchronizing with an External Device
59
Synchronizing with an External Device
Using Genlock synchronization, you can synchronize this camera’s video signal to that of an external 
video device. When a reference sync signal (analog blackburst or tri-level HD signal) is input through 
the GENLOCK terminal, the phases of the camera’s V and H sync will automatically be synchronized 
to it. The phase difference between the external Genlock signal and the camera is initially set to 0. The 
H phase can be adjusted within the range of approximately ±0.4 H (–1023 to 1023).
1 Open the [Genlock Adjustment] submenu.
[Other Functions] > [Genlock Adjustment]
2 Push the joystick up/down to select the value of the 
first field and then press SET to move to the next field.
• Change the rest of the fields in the same way to select the 
desired adjustment level (–1023 to 1023).
3 Select [Set] and then press SET.
NOTES
• When a suitable Genlock signal is input, the Genlock synchronization stabilizes within approximately 
10 seconds.
• When a suitable Genlock signal is detected, [Gen.] will flash on the upper right of the screen. When 
the camera locks on the external Genlock signal, [Gen.] will stop flashing and stay on.
• If the external Genlock signal is incorrect, the synchronization may not be stable.
Reference sync signal
BNC cable (commercially available)
[Other Functions]
[Genlock Adjustment]
[000]