2. Unplug range or disconnect power.
3. Remove warming drawer. See the “Remove Warming
Drawer” section for instructions. Locate gas pressure
regulator at rear of warming drawer compartment.
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator.
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “NAT” or “LP” position.
locate the “NAT” or “LP” position.
7. Turn over the spring retainer so the “LP” is showing on the
bottom.
8. Snap the spring retainer back into the cap.
9. Reinstall the cap onto the regulator.
To Convert Standard Surface Burners
1. Remove burner cap.
2. Using a T20
®
TORX
®
screwdriver, remove the burner base.
3. Apply masking tape to the end of a
7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
4. LP Gas orifice spuds are stamped with a number, marked
with 1 color dot, and have a groove in the hex area. Replace
the Natural gas orifice spud with the correct LP gas orifice
spud.
the Natural gas orifice spud with the correct LP gas orifice
spud.
Refer to the following chart for correct LP gas orifice spud
placement.
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
5. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with the package containing literature.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
TripleTier
®
Flame burner (on some models). See “To Convert
TripleTier
®
Flame Burners” in the “LP Gas Conversion”
section.
A. Gas pressure regulator
A. Access cap
B. Gasket
B. Gasket
C. Gas pressure regulator
D. Spring retainer
LP position
E. Spring retainer
NAT position
A
A
B
C
D
E
A. Igniter electrode
B. Gas tube opening
B. Gas tube opening
C. Burner cap
D. Burner base
D. Burner base
A. Groove
Burner Location
Burner Rating
Color
Size
Right front
Left front
Right rear
Left rear
5,000 Btu/h
13,000 Btu/h
10,000 Btu/h
5,000 Btu/h
Red
Green
Blue
Red
0.70 mm
1.10 mm
0.95 mm
0.70 mm
A
B
C
D
A