KitchenAid 30-Inch 4-Burner Dual Fuel Slide In Range, Architect® Series II 安装指南

下载
页码 44
21
2. Unplug range or disconnect power.
3. Remove warming drawer. See the “Remove Warming 
Drawer” section for instructions. Locate gas pressure 
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator.
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “NAT” or “LP” position. 
7. Turn over the spring retainer so the “LP” is showing on the 
bottom. 
8. Snap the spring retainer back into the cap. 
9. Reinstall the cap onto the regulator.
To Convert Standard Surface Burners
1. Remove burner cap. 
2. Using a T20
®
 TORX
®
 screwdriver, remove the burner base.
3. Apply masking tape to the end of a 
7 mm nut driver to help 
hold the gas orifice spud in the nut driver while changing it. 
Press nut driver down onto the gas orifice spud and remove 
by turning it counterclockwise and lifting out. Set gas orifice 
spud aside. 
4. LP Gas orifice spuds are stamped with a number, marked 
with 1 color dot, and have a groove in the hex area. Replace 
the Natural gas orifice spud with the correct LP gas orifice 
spud.
Refer to the following chart for correct LP gas orifice spud 
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
5. Place Natural gas orifice spuds in plastic parts bag for future 
use and keep with the package containing literature.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the 
TripleTier
®
 Flame burner (on some models). See “To Convert 
TripleTier
®
 Flame Burners” in the “LP Gas Conversion” 
section.
A. Gas pressure regulator
A. Access cap
B. Gasket
C. Gas pressure regulator
D. Spring retainer 
LP position
E. Spring retainer 
NAT position
A
A
B
C
D
E
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A. Groove
Burner Location
Burner Rating
Color
Size
Right front
Left front 
Right rear
Left rear
5,000 Btu/h
13,000 Btu/h
10,000 Btu/h
5,000 Btu/h
Red
Green
Blue 
Red
0.70 mm
1.10 mm
0.95 mm
0.70 mm
A
B
C
D
A