KitchenAid 30" Slide-Out Hood 尺寸示意图

下载
页码 2
PRODUCT MODEL NUMBERS
KHSU205W
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the model/serial
rating plate. The model/serial rating plate is located behind the left filter on the
rear wall of the range hood. 
Range hood location should be away from strong draft areas, such as windows,
doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions
provide minimum clearance. Consult your cooktop/ range manufacturer
installation instructions before making any cutouts.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home
Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or
when such standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition, or with local codes.
VENTING REQUIREMENTS
This range hood is factory set for venting through the roof or through the wall.
The vent system needed for installation is not included. A 6" (15.2 cm) round
vent system is recommended.
30" (76.2 cm) and 36" (91.4 cm) Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10267109
10/08/09
Roof Venting
A. 6" (15.2 cm) vent 
through the roof
B. Roof cap
A. 6" (15.2 cm) vent 
through the wall
B. Wall cap
A
B
A
B
Wall Venting
Calculating Vent System Length
The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 26 ft (8 m). For the best performance, use no more
than three 90° elbows.
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Example vent system - 6" (15.2 cm)
Non-Vented (recirculating) Installations Through the Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to the outside, the
range hood can be used in the non-vented (recirculating) version, using
an activated carbon filter. Recirculation Kit Part Number 4396565 is
available from the dealer or an authorized parts distributor. Damper
installation is not required.
Vent Piece
6" (15.2 cm)
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Maximum Length
= 26 ft (8 m)
1 - 90° elbow
1 - wall cap
9 ft (2.8 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 9.0 ft (2.8 m)
System length
= 14.0 ft (4.3 m)
90˚ elbow
3 ft
(0.93 m)
6 ft (1.8 m)
Wall cap
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
F. Cabinet
A
A
B
B
C
D
D
E
E
F
F
Page 1 of 2